Equipment Information: s/s construction; approximately 50in. W x 78in. H x 150in. L internal chamber dimenisons; pass thru design with dual doors on each end; steam heated: 150F degrees maximum operating temperature; 104F degrees normal operating temperature; heater capacity 642,700btuh @ 50psi; temperature rating F 150; steam heated; button and knob controls, readout meters; chart recorder; electrical: 480v/3ph/60hz
Full specifications
Equipment Information
s/s construction; approximately 50in. W x 78in. H x 150in. L internal chamber dimenisons; pass thru design with dual doors on each end; steam heated: 150F degrees maximum operating temperature; 104F degrees normal operating temperature; heater capacity 642,700btuh @ 50psi; temperature rating F 150; steam heated; button and knob controls, readout meters; chart recorder; electrical: 480v/3ph/60hz
Equipment Information: s/s construction' approximately 24in. x 24in. x 30in. chamber size; 9 shleves; rated up to 500F degress; 16kw heater; buttons, and PROTOCOL PLUS temperature touch pad with viewing screens controls; 500 degress maximum temperature; electrical: 480v/3ph/60hz/22.2 amps
Full specifications
Equipment Information
s/s construction' approximately 24in. x 24in. x 30in. chamber size; 9 shleves; rated up to 500F degress; 16kw heater; buttons, and PROTOCOL PLUS temperature touch pad with viewing screens controls; 500 degress maximum temperature; electrical: 480v/3ph/60hz/22.2 amps
Equipment Information: s/s construction in and out with single swing door and positive type latch; heating elements and circulating fan are mounted above the work area in a protected chamber; heated air is circulated horizontally; forced fresh air inlet with Hepa filter and a Hepa filter on the exhaust stack, magnehelic gauges on both hepa filters; equipped with a Partlow mic 6,000 programmable digital indicating temperature controller; Watlow 145 non-indicating over temperature control and Honeywell dr 4,500 round chart recorder mounted in a panel on the right side; maximum temperature 650F degrees; inside dimensions: W 36in. x L 36in. x H 60in.; outside dimensions are W 79in. x L 51in. x H 111in.; s/s oven cart, outside dimensions: W 28in. x L 33in. x H 46in. fabricated s/s roll in cart with 23 slots for trays; 1.5in. between trays, 14 trays included, tray size: 25.25in. x 33in. x 1in.
Full specifications
Equipment Information
s/s construction in and out with single swing door and positive type latch; heating elements and circulating fan are mounted above the work area in a protected chamber; heated air is circulated horizontally; forced fresh air inlet with Hepa filter and a Hepa filter on the exhaust stack, magnehelic gauges on both hepa filters; equipped with a Partlow mic 6,000 programmable digital indicating temperature controller; Watlow 145 non-indicating over temperature control and Honeywell dr 4,500 round chart recorder mounted in a panel on the right side; maximum temperature 650F degrees; inside dimensions: W 36in. x L 36in. x H 60in.; outside dimensions are W 79in. x L 51in. x H 111in.; s/s oven cart, outside dimensions: W 28in. x L 33in. x H 46in. fabricated s/s roll in cart with 23 slots for trays; 1.5in. between trays, 14 trays included, tray size: 25.25in. x 33in. x 1in.
Equipment Information: s/s internals; 8.3 cubic feet capacity; approximately 20in. W x 24in. H x 30in. D chamber; 8 s/s oven trays; electrically heated with 10.9kw heater; rated up to 212F degrees maximum operating temperature; push button, knob, meter readers and viewing screens; Baldor Industrial Motor: 400v/3ph/50hz/7 amps/1,425rpm; electrical: 400v/3ph/110.9kw
Full specifications
Equipment Information
s/s internals; 8.3 cubic feet capacity; approximately 20in. W x 24in. H x 30in. D chamber; 8 s/s oven trays; electrically heated with 10.9kw heater; rated up to 212F degrees maximum operating temperature; push button, knob, meter readers and viewing screens; Baldor Industrial Motor: 400v/3ph/50hz/7 amps/1,425rpm; electrical: 400v/3ph/110.9kw
Equipment Information: s/s construction and s/s product contact surfaces; 8.3 cubic feet capacity; 20in. W x 30in. D x 24in. H chamber; 280C maximum temperature; 9.8kw. electrical heater; controls: push button with digital readouts, meters and chart recorder; operation and maintenance manual; secured front door; electrical: 230v/3ph/60hz;
Full specifications
Equipment Information
s/s construction and s/s product contact surfaces; 8.3 cubic feet capacity; 20in. W x 30in. D x 24in. H chamber; 280C maximum temperature; 9.8kw. electrical heater; controls: push button with digital readouts, meters and chart recorder; operation and maintenance manual; secured front door; electrical: 230v/3ph/60hz;
Equipment Information: s/s construction; 8.3CF chamber capacity; 550F, 9kw. electric heater; manuals included; chamber dimensions: W 20in. x D 30in. x H 24in.; electrical: 480v/3ph/60hz
Full specifications
Equipment Information
s/s construction; 8.3CF chamber capacity; 550F, 9kw. electric heater; manuals included; chamber dimensions: W 20in. x D 30in. x H 24in.; electrical: 480v/3ph/60hz
Equipment Information: 2 door electric oven for tw2 carts on each side, double door unit; s/s construction in and out with double doors, positive type latch; heating elements and circulating fan are mounted above the work area in a protected chamber; heated air is circulated horizontally; controls include buttons with digital readout screens and magnehelic gauges on the unit; round chart recorder mounted in panel; s/s oven racks available: L 30in. x W 24in. x H 72in., each rack has 35 slots for trays, 1.5in. between trays, trays included and tray size is L 25in. x W 18in., additional racks and trays available; electrical: 480v
Full specifications
Equipment Information
2 door electric oven for tw2 carts on each side, double door unit; s/s construction in and out with double doors, positive type latch; heating elements and circulating fan are mounted above the work area in a protected chamber; heated air is circulated horizontally; controls include buttons with digital readout screens and magnehelic gauges on the unit; round chart recorder mounted in panel; s/s oven racks available: L 30in. x W 24in. x H 72in., each rack has 35 slots for trays, 1.5in. between trays, trays included and tray size is L 25in. x W 18in., additional racks and trays available; electrical: 480v
Equipment Information: s/s construction; touch pad and knob controls with viewing digital screens; Partlow MRC 7000 meter, and other meters; manuals included; Baldor Electric Hazardous Motor: 208-230-460/3ph/60hz/7.5hp; electrical: 460/3ph/36kw
Full specifications
Equipment Information
s/s construction; touch pad and knob controls with viewing digital screens; Partlow MRC 7000 meter, and other meters; manuals included; Baldor Electric Hazardous Motor: 208-230-460/3ph/60hz/7.5hp; electrical: 460/3ph/36kw
Equipment Information: designed for ISO Class 5 (formerly Class 100) cleanliness cycle throughout; fully welded s/s chamber; operates at up to 280 C for effective pyrogen removal; forced air convection system ensures uniform heat distribution, while a semi-automatic flush door enhances ease of use; chamber dimensions: 23.6in. W x 31.5in. H x 31.5in. D; external dimensions: 75.35in. W on load side, 65.12in. W on unload side x 82.52in. H at the highest point (exhaust duct) x 55.12in. D including door handles (oven itself is 51.2 ); chamber volume (ft /m ): 13.68ft /0.387 m ; electrical: 440v
Full specifications
Equipment Information
designed for ISO Class 5 (formerly Class 100) cleanliness cycle throughout; fully welded s/s chamber; operates at up to 280 C for effective pyrogen removal; forced air convection system ensures uniform heat distribution, while a semi-automatic flush door enhances ease of use; chamber dimensions: 23.6in. W x 31.5in. H x 31.5in. D; external dimensions: 75.35in. W on load side, 65.12in. W on unload side x 82.52in. H at the highest point (exhaust duct) x 55.12in. D including door handles (oven itself is 51.2 ); chamber volume (ft /m ): 13.68ft /0.387 m ; electrical: 440v
Equipment Information: s/s construction; 5,700 watts; interior measures approximately 40.9in. W x 47.2in. H x 33.5in. deep; 1,060 liter volume; 300C degrees maximum; 661lbs. maximum loading chamber; chamber D 33.5in. x H 47.2in. x W 47.2in.; CE rated; electrical: 208v/3ph/50-60hz
Full specifications
Equipment Information
s/s construction; 5,700 watts; interior measures approximately 40.9in. W x 47.2in. H x 33.5in. deep; 1,060 liter volume; 300C degrees maximum; 661lbs. maximum loading chamber; chamber D 33.5in. x H 47.2in. x W 47.2in.; CE rated; electrical: 208v/3ph/50-60hz
Equipment Information: aqueous design; s/s construction; 200kg. capacity; 185 F temperature rating; blower; steam heated with steam chest and air handler; drawings included; GE Fanuc HMI QuickPanel Control touch screen, 120v/1ph/60hz/24vdc, with ABB Commander 1900 chart recorder; oven box capacity: H 12in. x W 8in. x D 6in.; E-Stop button; electrical: 460v/3ph/60hz; overall dimensions: H 71in. x W 47in. x D 20in.
Full specifications
Equipment Information
aqueous design; s/s construction; 200kg. capacity; 185 F temperature rating; blower; steam heated with steam chest and air handler; drawings included; GE Fanuc HMI QuickPanel Control touch screen, 120v/1ph/60hz/24vdc, with ABB Commander 1900 chart recorder; oven box capacity: H 12in. x W 8in. x D 6in.; E-Stop button; electrical: 460v/3ph/60hz; overall dimensions: H 71in. x W 47in. x D 20in.
Equipment Information: 304L s/s internals; electrically heated; approximately 192 cubic feet capacity; approximately 48in. W x 72in. H x 128in. D chamber; 72kw heater; rated up to 800F degrees; Allen-Bradley PLC control; oven racks; electrical: 480v/3ph/60hz/5kva
Full specifications
Equipment Information
304L s/s internals; electrically heated; approximately 192 cubic feet capacity; approximately 48in. W x 72in. H x 128in. D chamber; 72kw heater; rated up to 800F degrees; Allen-Bradley PLC control; oven racks; electrical: 480v/3ph/60hz/5kva
Equipment Information: 3.7CF; exterior dimensions: W 25in. x H 32.5 x D 22.2; interior dimensions: W 18.3in. x H 23.9in. x D 14.5in.; heat up time 18 minutes; recovery time is 3 minutes; temperature uniformity is 3.5C degrees (based on 27 sensors); fluctuations: 0.4C degrees; electrical: 120v/1ph/14 amps
Full specifications
Equipment Information
3.7CF; exterior dimensions: W 25in. x H 32.5 x D 22.2; interior dimensions: W 18.3in. x H 23.9in. x D 14.5in.; heat up time 18 minutes; recovery time is 3 minutes; temperature uniformity is 3.5C degrees (based on 27 sensors); fluctuations: 0.4C degrees; electrical: 120v/1ph/14 amps
Equipment Information: rated up to 360C; 7.6 cubic feet capacity; electrically heated; temperature rating F 680; push button controls with digital readout screens; cord; 220v/1ph/60hz/21.5 amps
Full specifications
Equipment Information
rated up to 360C; 7.6 cubic feet capacity; electrically heated; temperature rating F 680; push button controls with digital readout screens; cord; 220v/1ph/60hz/21.5 amps