Maintenance & troubleshooting guide

Fluid Bed Maintenance and Troubleshooting

Browse the library

Related equipment: Browse our processing equipment.

There a several types of fluid beds. This information will address the maintenance of common components, common problems and troubleshooting, and unusually difficult problems that need to be addressed.

  • Common mechanical components: hydraulic pump, hydraulic pressing cylinders, spray nozzles, pneumatic shaking cylinders, quick action safety valve (QASV), gaskets, and overall machine integrity
  • Hydraulic pump: used to actuate the hyrdaulic pressing cylinders and seal the machine; it’s also used for turning bottoms
  • Oil levels, check levels and change oil after 1st 50 hours, and then every 2000 hours thereafter with VG-46 “oil only”
  • Control block, check the control block for signs of oil
  • Cycling, listen for excessive cycling
  • Oil filter, change the filter at annually
  • Hydraulic pressing cylinders: raises lower plenum to compress machine (150 bar - 2,250psi pressure)
  • Oil leaks, check around shaft seal and line connector
  • Piston, check for corrosion
  • Plenum, ensure both sides of the plenum raise uniformly
  • Cylinders, rebuild once a year
  • Liquid spray nozzles: used in the expansion chamber on the granulator, and also in Wurster and rotor applications
  • Integrity, check the physical integrity of the nozzle and coaxial connectors
  • O-rings, check all o-rings to esnure they’re in place and serviceable
  • Piston and needle pressure rings, esnure they are installed properly and operational
  • Pneumatic shaking clylinders: are located in the filter housing; shake filters reintroduce product into the processing area
  • Check to make sure that the cycle and stroke are uniform
  • Cylinder, esnure that the cylinder is not “slamming” on the downward stroke
  • Seal integrity, check for seal integrity, especially around the piston rods
  • Air leaks, listen for leaks during operation
  • Reuild this component annually
  • Silicone gaskets: are located throughout the machine to provide sealing between chambers and flanges
  • Check chamber gaskets for flaking or “flat” spots
  • Inflatable gaskets are to be checked for leaks, especially around the valve stem
  • Ensure that all window and door gaskets are in place and serviceable
  • Quick Action Safety Valve (QSSV): located in the exhaust and/or inlet air ducts to protect the machine and personnel from explosions within the fluid bed
  • Verify that the leather bellow is in place over the piston shaft and is in good shape
  • Ensure that the pneumatic cylinder operates smoothly and that the plunger fully engages the flanges
  • Tank pressure should be at 70 bar
  • Sheer cap, check the “installation of the sheer cap” date mark, if its over 3 years, the bottle must be refilled
  • Bursting disc, change the disc on the QASV with every bottle exchange
  • Exhaust air filters: located in the filter housing, it retains product in the machine tower
  • Filter material should be checked for any holes or worn areas
  • Ensure that the tightening strap securely retains the filter to the filter flange
  • Inertia reel safety device, verify that it operares as designed
  • Broken bag detector, verify its operation and adjust its sensitivity as needed
  • Overall machine integrity: the machine should be checked on a regular basis
  • Check, look for any cracks, dents of other conditions that may weaken the steel
  • Ensure that all windows, doors and other openings to the machine are properly sealed
  • Whistling, listen for whistling sounds which would indicate an air leak
  • Common problems and troubleshooting procedures
  • Problem: Machine won’t compress?
  • Verify air pressure to the hydraulic pump; pressure is typically set 6 bar (90psi)
  • An interlock has not been made; most common is the “bowl-in-place” limit switch
  • Hydraulic pump has seized, sometimes it can be termporarily rectified by adding a few drops of oil in the shuttle valve; however, it should probably be rebuilt as soon as possible
  • Problem: Inflatable gasket will not inflate, or, over inflates?
  • Check air pressure, it should be set at 3 to 3.5 bar
  • If not inflating check all interlocks; most machines will not permit inflation until certain conditions are met
  • Pneumatic micro-switch may be sticking; very common with pneumatic panels, the switch must be identified and replaced
  • Problem: QASV has activated with no apparent signs of overpressure?
  • Whisker switch in the explosion duct has been tripped; usually an operator error done by cleaning
  • Whisker switch electrical terminal has corroded allowing for a bridge of current; very common as many explosion ducts are partially exposed to the elements
  • Power surge or brownout, QASV circuit must be protected or a power spike can activate the device
  • Problem: Spray nozzle doesn’t work, or, over-wets during operation?
  • Check the control and atomization air pressure and ensure that it’s set to pre-established presets
  • Ensure that the needle and piston pressure springs are installed and operational
  • Check O-rings, be sure they’re installed and serviceable; if worn or missing air-liquid, they can co-mingle and result in over-wetting or dripping
  • Problem: Shaking cylinders don’t operate or “slam” on the downward stroke”?
  • Verify supply air pressure is set a 6 bar, and that the supply is great enough to prevent the cylinders from “starving for air”
  • Toggle limit switches, check to see if the cylinder retracts or extends; if this works, adjust the limit switche(s) to their proper position
  • If limit switches are positioned properly, listen for air escaping from the cylinder; typically shaft seals will wear allowing air leaks that prohibit full strokes
  • Problem: If your cylinder is “slamming” on the down-stroke?
  • Adjust cushioning screws on both the lower and upper portion of the cylinder; this will adjust the amount of air left in the cylinder after stroking
  • Adjust the muffler on the solenoid to slow down the exhaust air
  • Problem: Filter cable keeps breaking or fraying?
  • Most common reason for filter cable damage is not backing-off on the hand wench by at least two turns
  • Cable has come off the pulleys, or was damaged during a filter change
  • Problem: Filter retaining bolt is constatnly breaking?
  • Length of the kevlar ropes between the suspension ring and the filter flange are too short prohibiting full retraction of the filter assembly
  • Not backing-off two turns of the winch
  • Problem: Product is “blowing-by” the exhaust air filters?
  • Confirm amount of “blow-by” by examining the filter housing; is there striations or complete coverage of the filter housing?
  • Striations, if there are striations, check the following: inflatable gasket, use the water test to esnure the proper seal between the filter flange and the machine wall; check and make sure there is no spacing between the tightening strap and filter flange; check for holes in the filter material, especially around the filter flange; if there is complete coverage, check the following: are you using the correct type of filter, compare the micron rating of the filter with that of the product; ensure that the filter is free floating between the suspension ring and the filter flange, stretching the filter will create larger pore sizes
  • Unusual problems
  • Problem: Experiencing constant “overpressures” in the machine, causing ex-panels to blow out?
  • Used an aqueous based spray coating, so no solvents can be blamed for cauing the explosion
  • Discovered that an operator increased the atomization air pressure on the spray nozzle to over 6 bar, thereby pressurizing the fluid bed and causing the panels to blow out
  • Problem: The clean side of the HEPA filter in the air handler were covered with dust, if was confirmed that it was the product produced in the fluid bed. How did the powder get on the clean side of the HEPA’s?
  • Machine was located in a pressurized room
  • During cleaning the machine was opened and the room pressure forced powder through the inlet air duct into the air handler, thus collecting on the clean side of the HEPA filters
  • Problem: During a routine PM it was discovered that the Nitrogen bottle on the QASV was at zero pressure. No one was aware of any discharge of the tanks or activiation of the QASV circuit?
  • When inspecting the bottles, it was found that they were detonated incidating the system was activated
  • Upon investigation it was determined that one of the operators activated the system during cleaning; instead of reporting it, he changed the bursting disc and reset the system, that person was fired