Related equipment: Browse our processing equipment.
There are several types of coating systems: inlet air system AHU, exhaust air system, spraying and pump systems, fully perforated or partially perforated pan type, controls systems, eletrical pneumatic systems and utilities (chilled water, steam air) systems. The following information is a general overview of good maintenance practices to keep your system up and running
- General maintenance checks that should be included in the annual inspection of the coater
- Pan support contact points should be clean and free of any buildup
- Check hardware securing the sheet metal and support member to the frame for tightness
- Pneumatic and solution tubing should be checked for cracks, crimps, or plugs, replace as necessary
- Fittings are to be checked on a monthly basis, and cleaned or replaced as needed
- Solution tubing and air should be inspected weekly
- Tubing inside the pan should be replaced every 6 months
- Front caster wear should be checked every 6 months
- Exhaust plenum cover gaskets should be replaced annually
- Front door gasket, replace annualy and check periodically
- Front mouth ring seal, adjust periodically or replace annually
- Drive assembly maintenance: drive chain has an adjustable idler sprocket that applies constant pressure to maintain tension
- Chain tension, adjust the tension for 1/2” of movement in the center of the chain; 1” of play is typical in the roller chain
- Check the tightener for the roller chain, and the drain plug
- Oil changes, see the vendor information for frequency of gearbox oil changes and the type of oil required
- Lubrication schedule: this is a schedule that needs to be TAKEN SERIOUSLY
- Pan drive chain, lubricate every 6 months; use chain lube oil
- Pan drive gearbox lubricate every 2 months, or every 750 hours of operation; use United Lubricants Industrial Gear Compound 150 320, or Mobil SHC-629 or an equivalent, or, use Chevron FM 460X USDA-HI food grade
- Rear pillow block bearing, lubricate every 6 months; use Exxon Andox “C” or an equivalent lubricant
- Solution pump gearbox, lubricate every 750 hours of operation; use SAE 140 gear lube
- Autowash pump crankcase, lubricate every 500 hours of operation; use SAE 30 W non-detergent
- Inlet blower fan bearing, lubricate every 2 months; use NLGI Grade 2 Multi-Purpose grease
- Inlet blower motor, lubricate every 6 months; use Shell Dolium R “TYP.”
- Exhaust blower, lubricate every 2 months; use lithium based NLGI grade 2
- Common maintenance problems that my be easily resolved
- Filter loading problems, high pressure drop
- Leaking tubing and fittings
- Air bubbles in the solution line after pumping
- Material build-up in the exhaust duct
- Peristaltic pump tubing may be the wrong type, or my need to be replaced
- Gear pumps need routine maintenance
- Electrical/Pneumatic maintenance issues
- Electrical diagrams include digial inputs, digital outputs, analog inputs, and analog outputs; ensure that your operators are well-trained in the operation of their equipment, know the information on the various screens, and have a manual (or other backup) and diagrams readily available in case an issue arises
- Pneumatic diagram include pneumatic inputs and pneumatic outputs; ensure that your operators are well-trained in the operation of their equipment, know the information on the various screens, and have a manual (or other backup) and diagrams readily available in case an issue arises
- Process and machine control: interlock and conditions
- Intlet fan running: on-button is depressed, solution selected, isolation valves armed
- Exhaust fan running: on-button is depressed, solution selected, isolation valves armed, wash pump off
- Pan motor running: on-button depressed, pan covers on
- Solution pump running: on-button depressed
- Air heater on: on-button depressed, inlet fan on
- Spray: exhaust fan on, inlet fan on, pump on, heat on, pan running
- Critical faults: emergency stop; main air pressure; control power; isolation valve trouble; isolation valve alarm; PLC communication
- Digital faults: inlet blower; exhaust blower; pan motor; pump turning; pan door closed; pump turning; plugged filter (HEPA or Pre); torn filter (HEPA or Pre) UPS fault; pan covers
- Analog faults: high inlet temperature