Major areas of concern for blender maintenance includes the following: installation, alignment and leveling; lubrication; drive alignment; discharge valve; vented covers; intensifier bar assembly; and cleaning of the vessel.

  • Installation
  • Alignment and leveling: be sure your surface and your trunions are level
  • Lubrication
  • Main drive reducer should have its oil filled and ready to operate; drain the oil and refill after the first 100 hours; change the oil every 2,500 hours or 6 months
  • Pillow block bearings: are grease packed at the factory with NLGI grade #2 lithium base grease
  • Trunnion roller assemmbly: maintenance is required if the conditions are dusty, or, if they begin to make noise
  • Idle trunnion bearings: no maintenance required under normal circumstances
  • Poly cahin drive: requires no lubrication
  • Roller chain and sprocket lubrication: correct lubrication is essential to obtain long life of the chain drive: 20 to 40 degrees F = SAE 20 lubricant; 40 to 100 degrees F = SAE 30 lubricant; 100 to 120 degrees F = SAE 40 lubricant; and 120 to 140 degrees F = SAE 50 lubricant
  • Maintenance hours
  • Motors: inspect at least every 1000 hours; change oil according to the manufacturer’s manual or tag
  • Main drive reducer: inspect at least every 500 hours; change oil at least every 2500 hours
  • Poly chain drive: inspect at least every 500 hours
  • Drive chain and sprocket: inspect at least every 200 hours; change oil every 100 hours, or refer to the maintenance lubrication section of the manual
  • Drive gears: inspect at least every 200 hours; grease every 100 hours, or refer to the maintenance lubrication section of the manual
  • Pillow block bearings: inspect at lease every 200 hours; grease every 1000 hours
  • Rotary union: inspect at least every 200 hours; grease every 200 hours
  • V-belts: inspect at least every 100 hours
  • Poly chain drive adjustments
  • Gates poly chain GT belts: apply the deflection force at the mid span length
  • Tension adjustments up to 30 lbs., use Gates’ 30 lb. pencil type tester
  • Greater than 30 lbs., use Gates’ 66 lb. double barrel tester
  • Discharge valve maintenance
  • DO NOT hammer the handle, or use a pipe extension rod
  • DO NOT attempt to force the vane parallel with the valve body
  • Cover gaskets maintenance
  • To maintain a dust-free operation, these units are provided with soft, rubber gasket covers, 50 to 60 durometer, between the cover and the shell
  • Periodically check the gaskets for softness, they’ll harden with time
  • Replace the gaskets at least once a year
  • Avoid cross batch contamination
  • DO NOT over tighten the “tee bolt”
  • DO NOT use a wrench on the “tee bolt” to gain additional leverage
  • Over tightening may cause severe damage to the covers
  • Blenders with vented covers
  • Filter media should be considered expendable
  • Easy access filters when they become plugged with material, or excessively damp, they should be replaced with clean ,new, dry “easy access” filters
  • Intensifier assembly
  • Routine maintenance should include the flanged cartridge assembly, O-ring, and high speed intensifier bar
  • Flanged cartridge and air seals
  • Routine maintenance should include tamper roller bearings, v-ring seal, cartridge air seal housing, cartridge air seal distributor, ring seal, and oil seal
  • Intensifier drive end assembly with flanged cartridge and packed seals
  • Routine maintenance should include checking the flanged cartridge assembly, O-ring, pin intensifier, tamper roller bearings, cartridge packaging housing, oil seal and ring seal
  • Double hung intensifier bar intensifier drive end assembly
  • Routine maintenance should include checking the v-ring seal, felt packaging rings, oil seal, Timken bearing cup/cone, Timken lockwasher, Timken locknut, intensifier drive shaft, oil seal, and o-ring
  • V-Ring setup detail drive end
  • Routine maintenance should include checking the seal housing cover, gauge block, seal collar, v-ring seal
  • Double supported intensifier bar intensifier idel end assembly
  • Routine maintenance should include checking the v-ring seal, and felt packing rings
  • V-ring setup detail idle end
  • Routine maintenance should include checking the v-ring seal, seal collar, and gauge block
  • Vessel Cleaning
  • Detergent, fill the vessel 1/3 with water, with or without detergent
  • Close all access covers, and rotate vessel
  • Drain and rinse if required
  • Remove and clean cover seals